The MCC1 is a simple to use, serial data
communications hub and interface device providing a
high level of integrity in data transfers.
It is designed for remote monitoring and control of
industrial communication applications and can be
factory customised for specific applications.
More Details
Communication:
Wireless communication with any radio enabled ICT
International instrument within 250m.
Portable, easy to use via ICT International
software interface.
Any radio enabled ICT International Instrument
connects directly into any Windows based
computer via USB cable.
Features
Industrial quality product
Wired interfaces protected against lightning and other
transients. Includes separate local earth connection.
Wired interfaces optically isolated from the USB port
and power supply to simplify connections between
equipment with different power and ground potentials.
Data encryption prevents eavesdropping and hacking
of transmissions.
Sophisticated error checking and message resending
ensures error free data transfers.
Specifications
Sensor Specifications
Communication
Communication Ports
2.4GHz wireless
USB
RS-485
RS-232
TTL-3V
TTL-5V
SDI-12/S18
Operating
Operating modes
2.4GHz low power radio to serial data port
ICT Compatible USB - 2.4GHz Radio Modem
This mode is used to connect, wirelessly, to any radio enabled ICT instrument using ICT Utility software.
ICT RF Logger (USB or serial port – 2.4GHz Radio Logger)
This mode is used when the MCC is used in conjunction with an eState CellVisor or ICT's Soft Logger software to provide PC based logging.
USB to Optically Isolated Serial Port Modem.
In this mode the MCC is a USB to serial converter. Serial modes are selectable and can be either RS485, RS232, TTL-3V, TTL-5V or SDI-12/SI8.
Multiprotocol Wireless Serial Port to Serial Port Modem
This mode is designed to be used with two paired MCCs. Each MCC can be configured to act as RF–USB or RF–Serial converter. The paired MCCs can then be USB–RF-Serial, USB–RF-USB or Serial-RF–Serial. (The serial ports can be any one of RS232, RS485,
3V TTL, 5V TTL, Monibus or SDI-12).
In USB-RF-USB mode, two computers can communicate through PC virtual COM ports.
In Serial-RF-Serial mode, two paired MCCs can provide any combination of RS-485/
RS-232/TTL-3V/TTL-5V/SDI-12/SI8 to RS-485/RS-232/TTL-3V/TTL-5V/SDI-12/SI8.
Signal Strength Test.
This mode can be used to test the radio link between the MCC and a device compatible
with RSSI, (Received Signal Strength Indication), test protocol. ICT Instruments with
generic comms board firmware 2-0-4 or above are compatible with the RSSI test protocol.
Power
Transmitter Power
100dBmW max.
Power Supply
Powered from USB or external 8 - 30V DC supply. (Note: supply current 110mA @ 12V DC.
Operating Conditions
Radio Range
Up to 1km with whip antennas and up to 5km with high gain antennas, line of sight, depending on
conditions.
Data Rate
115kbps maximum depending on mode of operation.
Other Protocols
Supported
Supports SDI12 v1.3 Basic Command Set.
Other